A simple and inexpensive test-rig for evaluating the performance of motion sensors used in movement disorders research

dc.contributor.authorPerera, Thushara
dc.contributor.authorYohanandan, Shivanthan
dc.contributor.authorMcDermott, Hugh
dc.date.accessioned2015-12-23T22:47:50Z
dc.date.available2015-12-23T22:47:50Z
dc.date.issued2015-05-29
dc.description.abstractSince the advent of electromyogram recording, precise measures of tremor and gait have been used to study movement disorders such as Parkinson’s disease. Now, a wide range of accelerometers and other motion-tracking technologies exist to better inform researchers and clinicians, yet such systems are rarely tested for accuracy or suitability before use. Our inexpensive test-rig can produce sinusoidal displacements using a simple cantilever system driven by a subwoofer. Controlled sinusoids were generated using computer software, and the displacement amplitudes of the test-rig were verified with fiducial marker tracking. To illustrate the use of the test-rig, we evaluated an accelerometer and an electromagnetic motion tracker. Accelerometry recordings were accurate to within ±0.09 g of actual peak-to-peak amplitude with a frequency response close to unity gain between 1 and 20 Hz. The electromagnetic sensor underestimated peak displacement by 2.68 mm, which was largely due to a diminishing gain with increasing frequency. Both sensors had low distortion. Overall sensitivity was limited by noise for the accelerometer and quantisation resolution for the electromagnetic sensor. Our simple and low-cost test-rig can be used to bench-test sensors used in movement disorders research. It was able to produce reliable sinusoidal displacements and worked across the 1- to 20-Hz frequency range.en_US
dc.identifier.citationPerera, T., S. A. Yohanandan & H. J. McDermott (2015). A simple and inexpensive test-rig for evaluating the performance of motion sensors used in movement disorders research. Medical & biological engineering & computing: [epub ahead of print].en_US
dc.identifier.issn1741-0444
dc.identifier.urihttp://repository.bionicsinstitute.org:8080/handle/123456789/160
dc.language.isoenen_US
dc.publisherSpringer Berlin Heidelbergen_US
dc.subjectAccelerometeren_US
dc.subjectElectromagneticen_US
dc.subjectMovement disordersen_US
dc.subjectMotion trackingen_US
dc.subjectven_US
dc.titleA simple and inexpensive test-rig for evaluating the performance of motion sensors used in movement disorders researchen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2015Perera - cover.pdf
Size:
122.89 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections