Virtual electrodes by current steering in retinal prostheses

dc.contributor.authorDumm, Gerald
dc.contributor.authorFallon, James
dc.contributor.authorWilliams, Chris
dc.contributor.authorShivdasani, Mohit
dc.date.accessioned2015-04-01T00:43:22Z
dc.date.available2015-04-01T00:43:22Z
dc.date.issued2014
dc.description.abstractPURPOSE:Retinal prostheses are an approved treatment for vision restoration in retinal degenerative diseases; however, present implants have limited resolution and simply increasing the number of electrodes is limited by design issues. In cochlear implants, virtual electrodes can be created by simultaneous stimulation of adjacent physical electrodes (current steering). The present study assessed whether this type of current steering can be adapted for retinal implants. METHODS:Suprachoroidal electrode arrays were implanted in four normally sighted cat eyes. Electrode pairs were driven simultaneously at different current levels and current ratios. Multiunit spiking activity in the visual cortex was recorded. Spike distribution across channels enabled generation of cortical activation maps and calculation of centroid positions. For each current configuration, centroid shifts between two virtual electrodes were compared to shifts obtained from physical electrode stimulation. RESULTS:Using current steering, virtual electrodes with different cortical activation maps could be created. Cortical centroids were found to shift as a function of the current ratio used for virtual electrodes and were similar to the centroid shifts seen when using physical electrodes. In addition, the cortical response to stimulation of a physical electrode could be reproduced by applying current steering to electrodes on either side of the physical electrode. CONCLUSIONS:These results suggest that current steering can alter activation patterns in the visual cortex and could enhance visual perception in retinal implants by eliciting phosphene percepts intermediate between those elicited by physical electrodes. These results inform development of new electrode arrays that can take advantage of current steering.en_US
dc.description.sponsorshipThis work was supported by the Australian Research Council through its Special Research Initiative in Bionic Vision Science and Technology awarded to Bionic Vision Australia, the Bertalli Family Foundation to the Bionics Institute, and a project grant from the National Health and Medical Research Council, Australia (Project#1063093). The Bionics Institute wishes to acknowledge the support it receives from the Victorian Government through its Operational Infrastructure Program.en_US
dc.identifier.citationDumm, G., Fallon, J. B., Williams, C. E., & Shivdasani, M. N. (2014). Virtual electrodes by current steering in retinal prostheses. Investigative Ophthalmology & Visual Science, 55(12), 8077-8085.en_US
dc.identifier.issn1552-5783 (Electronic) 0146-0404 (Linking)
dc.identifier.urihttp://repository.bionicsinstitute.org:8080/handle/123456789/115
dc.language.isoenen_US
dc.publisherARVOen_US
dc.subjectcurrent steeringen_US
dc.subjectelectrophysiologyen_US
dc.subjectresolutionen_US
dc.subjectretinal implanten_US
dc.subjectvisual cortexen_US
dc.titleVirtual electrodes by current steering in retinal prosthesesen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2015-04 Dumm Current Steering.pdf
Size:
747.27 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections