Virtual electrodes by current steering in retinal prostheses
dc.contributor.author | Dumm, Gerald | |
dc.contributor.author | Fallon, James | |
dc.contributor.author | Williams, Chris | |
dc.contributor.author | Shivdasani, Mohit | |
dc.date.accessioned | 2015-04-01T00:43:22Z | |
dc.date.available | 2015-04-01T00:43:22Z | |
dc.date.issued | 2014 | |
dc.description.abstract | PURPOSE:Retinal prostheses are an approved treatment for vision restoration in retinal degenerative diseases; however, present implants have limited resolution and simply increasing the number of electrodes is limited by design issues. In cochlear implants, virtual electrodes can be created by simultaneous stimulation of adjacent physical electrodes (current steering). The present study assessed whether this type of current steering can be adapted for retinal implants. METHODS:Suprachoroidal electrode arrays were implanted in four normally sighted cat eyes. Electrode pairs were driven simultaneously at different current levels and current ratios. Multiunit spiking activity in the visual cortex was recorded. Spike distribution across channels enabled generation of cortical activation maps and calculation of centroid positions. For each current configuration, centroid shifts between two virtual electrodes were compared to shifts obtained from physical electrode stimulation. RESULTS:Using current steering, virtual electrodes with different cortical activation maps could be created. Cortical centroids were found to shift as a function of the current ratio used for virtual electrodes and were similar to the centroid shifts seen when using physical electrodes. In addition, the cortical response to stimulation of a physical electrode could be reproduced by applying current steering to electrodes on either side of the physical electrode. CONCLUSIONS:These results suggest that current steering can alter activation patterns in the visual cortex and could enhance visual perception in retinal implants by eliciting phosphene percepts intermediate between those elicited by physical electrodes. These results inform development of new electrode arrays that can take advantage of current steering. | en_US |
dc.description.sponsorship | This work was supported by the Australian Research Council through its Special Research Initiative in Bionic Vision Science and Technology awarded to Bionic Vision Australia, the Bertalli Family Foundation to the Bionics Institute, and a project grant from the National Health and Medical Research Council, Australia (Project#1063093). The Bionics Institute wishes to acknowledge the support it receives from the Victorian Government through its Operational Infrastructure Program. | en_US |
dc.identifier.citation | Dumm, G., Fallon, J. B., Williams, C. E., & Shivdasani, M. N. (2014). Virtual electrodes by current steering in retinal prostheses. Investigative Ophthalmology & Visual Science, 55(12), 8077-8085. | en_US |
dc.identifier.issn | 1552-5783 (Electronic) 0146-0404 (Linking) | |
dc.identifier.uri | http://repository.bionicsinstitute.org:8080/handle/123456789/115 | |
dc.language.iso | en | en_US |
dc.publisher | ARVO | en_US |
dc.subject | current steering | en_US |
dc.subject | electrophysiology | en_US |
dc.subject | resolution | en_US |
dc.subject | retinal implant | en_US |
dc.subject | visual cortex | en_US |
dc.title | Virtual electrodes by current steering in retinal prostheses | en_US |
dc.type | Article | en_US |