An improved cochlear implant electrode array for use in experimental studies

dc.contributor.authorShepherd, Robert
dc.contributor.authorVerhoeven, Kristien
dc.contributor.authorXu, Jin
dc.contributor.authorRisi, Frank
dc.contributor.authorFallon, James
dc.contributor.authorWise, Andrew
dc.date.accessioned2017-08-23T06:38:26Z
dc.date.available2017-08-23T06:38:26Z
dc.date.issued2011-03
dc.description.abstractExperimental studies play an important role in establishing the safety and efficacy of cochlear implants and they continue to provide insight into a new generation of electrode arrays and stimulation strategies. One drawback has been the limited depth of insertion of an electrode array in experimental animals. We compared the insertion depth and trauma associated with the insertion of Cochlear Ltd's Hybrid-L (HL) array with a standard 8 ring array in cat cochleae. Both arrays were inserted into cadaver cochleae and an X-ray recorded their anatomical location. The implanted cochlea was serially sectioned and photographed at 300 mum intervals for evidence of electrode insertion trauma. Subsequently two cats were chronically implanted with HL arrays and electrically-evoked potentials recorded over a three month period. Mean insertion depth for the HL arrays was 334.8 degrees (SD = 21 degrees ; n = 4) versus 175.5 degrees (SD = 6 degrees ; n = 2) for the standard array. This relates to approximately 10.5 mm and 6 mm respectively. A similar insertion depth was measured in a chronically implanted animal with an HL array. Histology from each cadaver cochleae showed that the electrode array was always located in the scala tympani; there was no evidence of electrode insertion trauma to the basilar membrane, the osseous spiral lamina or the spiral ligament. Finally, evoked potential data from the chronically implanted animals exhibited significantly lower thresholds compared with animals implanted with a standard 8 ring array, with electrical thresholds remaining stable over a three-month observation period. Cochlear Ltd's HL electrode array can be safely inserted approximately 50% of the length of the cat scala tympani, placing the tip of the array close to the 4 kHz place. This insertion depth is considerably greater than is routinely achieved using a standard 8-ring electrode array ( approximately 12 kHz place). The HL array evokes low thresholds that remain stable over three months of implantation. This electrode array has potential application in a broad area of cochlear implant related research.en_US
dc.description.sponsorshipWe are grateful for funding support from the National Institutes of Health NIDCD (HHS-N-263-2007-00053-C), Cochlear Ltd, the NH&MRC of the Australian Government and the Victorian State Government through their Operational Infrastructure Support scheme. We thank Ms. Helen Feng and Godofredo Timbol for their contributions to this study and acknowledge the HEARing Cooperative Research Centre for access to the Microfocus X-ray Imaging facility.en_US
dc.identifier.citationShepherd, R., K. Verhoeven, J. Xu, F. Risi, J. Fallon, and A. Wise. 2011. An improved cochlear implant electrode array for use in experimental studies. Hearing Research. 277(1-2): 20-7.en_US
dc.identifier.issn1878-5891 (Electronic) 0378-5955 (Linking)
dc.identifier.urihttp://repository.bionicsinstitute.org:8080/handle/123456789/255
dc.language.isoenen_US
dc.publisherElevieren_US
dc.subjectAcoustic stimulationen_US
dc.subjectAuditory thresholden_US
dc.subjectCochlear implantsen_US
dc.subjectElectrical stimulationen_US
dc.titleAn improved cochlear implant electrode array for use in experimental studiesen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2011_Shepherd_Animprovedcochlear.pdf
Size:
56.97 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections