Browsing by Author "Prawer, Steven"
Now showing 1 - 9 of 9
Results Per Page
Sort Options
- ItemAn all-diamond, hermetic electrical feedthrough array for a retinal prosthesis(Elsevier, 2014-01) Ganesan, Kumaravelu; Garrett, David; Ahnood, Arman; Shivdasani, Mohit; Tong, Wei; Turnley, Ann; Fox, Kate; Meffin, Hamish; Prawer, StevenThe interface between medical implants and the human nervous system is rapidly becoming more and more complex. This rise in complexity is driving the need for increasing numbers of densely packed electrical feedthroughs to carry signals to and from implanted devices. This is particularly crucial in the field of neural prosthesis where high resolution stimulating or recording arrays near peripheral nerves or in the brain could dramatically improve the performance of these devices. Here we describe a flexible strategy for implementing high density, high count arrays of hermetic electrical feedthroughs by forming conducting nitrogen doped nanocrystalline diamond channels within an insulating polycrystalline diamond substrate. A unique feature of these arrays is that the feedthroughs can themselves be used as stimulating electrodes for neural tissue. Our particular application is such a feedthrough, designed as a component of a retinal implant to restore vision to the blind. The hermeticity of the feedthroughs means that the array can also form part of an implantable capsule which can interface directly with internal electronic chips. The hermeticity of the array is demonstrated by helium leak tests and electrical and electrochemical characterisation of the feedthroughs is described. The nitrogen doped nanocrystalline diamond forming the electrical feedthroughs is shown to be non cyctotoxic. New fabrication strategies, such as the one described here, combined with the exceptional biostability of diamond can be exploited to generate a range of biomedical implants that last for the lifetime of the user without fear of degradation.
- ItemDevelopment and Characterization of a Sucrose Microneedle Neural Electrode Delivery System(Wiley, 2017-12) Apollo, Nicholas; Jiang, Jonathon; Cheung, Warwick; Baquier, Sebastien; Lai, Alan; Mirebedini, Azadeh; Foroughi, Javad; Wallace, Gordon; Shivdasani, Mohit; Prawer, Steven; Chen, Shou; Williams, Richard; Cook, Mark; Nayagam, David; Garrett, DavidStable brain–machine interfaces present extraordinary therapeutic and scientific promise. However, the electrode–tissue interface is susceptible to instability and damage during long-term implantation. Soft, flexible electrodes demonstrate improved longevity, but pose a new challenge with regard to simple and accurate surgical implantation. A high aspect ratio water-soluble microneedle is developed based on sucrose which permits straightforward surgical implantation of soft, flexible microelectrodes. Here, a description of the microneedle manufacturing process is presented, along with in vitro and in vivo safety and efficacy assessments. Successful fabrication requires control of the glass transition temperature of aqueous sucrose solutions. The insertion force of 5 different microneedle electrode vehicles is studied in agarose brain phantoms, with the sucrose microneedle eliciting the lowest insertion force and strain energy transfer. Short- and long-term assessments of the pathological response to sucrose microneedle implantations in the brain suggest minimal tissue reactions, comparable to those observed following stainless-steel hypodermic needle punctures. Finally, microelectrodes fabricated from graphene, carbon nanotubes, or platinum are embedded in sucrose microneedles and implanted into an epileptic rat model for 22 d. All electrodes are functional throughout the implantation period, with the graphene electrode exhibiting the largest seizure signal-to-noise ratio and only modest changes in impedance.
- ItemDirect fabritcation of 3D graphene on nanoporous anodic alumina by plasma-enhanced chemical vapour deposition(Scientific Reports, 2016-01-25) Zhan, Hualin; Garrett, David; Apollo, Nicholas; Ganesan, Kumaravelu; Lau, Desmond; Prawer, Steven; Cervenka, JiriHigh surface area electrode materials are of interest for a wide range of potential applications such as super-capacitors and electrochemical cells. This paper describes a fabrication method of threedimensional (3D) graphene conformally coated on nanoporous insulating substrate with uniform nanopore size. 3D graphene films were formed by controlled graphitization of diamond-like amorphous carbon precursor films, deposited by plasma-enhanced chemical vapour deposition (PECVD). Plasma-assisted graphitization was found to produce better quality graphene than a simple thermal graphitization process. The resulting 3D graphene/amorphous carbon/alumina structure has a very high surface area, good electrical conductivity and exhibits excellent chemically stability, providing a good material platform for electrochemical applications. Consequently very large electrochemical capacitance values, as high as 2.1 mF for a sample of 10 mm3, were achieved. The electrochemical capacitance of the material exhibits a dependence on bias voltage, a phenomenon observed by other groups when studying graphene quantum capacitance. The plasma-assisted graphitization, which dominates the graphitization process, is analyzed and discussed in detail.
- ItemElectrical stimulation of retinal ganglion cells with diamond and the development of an all diamond retinal prosthesis(Elsevier, 2012-08) Hadjinicolaou, Alex; Leung, Ronald; Garrett, David; Ganesan, Kumaravelu; Fox, Kate; Nayagam, David; Shivdasani, Mohit; Meffin, Hamish; Ibbotson, Michael; Prawer, Steven; O'Brien, Brendan
- ItemElectrically conducting diamond films grown on platinum foil for neural stimulation(IOP Publishing, 2019-07) Sikder, Kabir; Shivdasani, Mohit; Fallon, James; Seligman, Peter; Ganesan, Kumaravelu; Villalobos, Joel; Prawer, Steven; Garrett, DavidObjective With the strong drive towards miniaturization of active implantable medical devices and the need to improve the resolution of neural stimulation arrays, there is keen interest in the manufacture of small electrodes capable of safe, continuous stimulation. Traditional materials such as platinum do not possess the necessary electrochemical properties to stimulate neurons safely when electrodes are very small (i.e. typically less than about 300 um (78400 microm2)). While there are several commercially viable alternative electrode materials such as titanium nitride and iridium oxide, an attractive approach is modification of existing Pt arrays via a high electrochemical capacitance material coating. Such a composite electrode could still take advantage of the wide range of fabrication techniques used to make platinum-based devices. The coating, however, must be biocompatible, exhibit good adhesion and ideally be long lasting when implanted in the body. Approach Platinum foils were roughened to various degrees with regular arrays of laser milled pits. Conducting diamond films were grown on the foils by microwave plasma chemical vapor deposition. The adhesion strength of the films to the platinum was assessed by prolonged sonication and accelerated aging. Electrochemical properties were evaluated and compared to previous work. Main results In line with previous results, diamond coatings increased the charge injection capacity of the platinum foil by more than 300% after functionalization within an oxygen plasma. Roughening of the underlying platinum substrate by laser milling was required to generate strong adhesion between the diamond and the Pt foil. Electrical stress testing, near the limits of safe operation, showed that the diamond films were more electrochemically stable than platinum controls. Significance The article describes a new method to protect platinum electrodes from degradation in vivo. A 300% increase in charge injection means that device designers can safely employ diamond coated platinum stimulation electrodes at much smaller sizes and greater density than is possible for platinum. .
- ItemIn Vivo Feasibility of Epiretinal Stimulation Using Ultrananocrystalline Diamond 1 Electrodes(IOP Publishing, 2020-07) Shivdasani, Mohit; Evans, Mihailo; Burns, Owen; Yeoh, Jonathon; Allen, Penelope; Nayagam, David; Villalobos, Joel; Abbott, Carla; Luu, Chi; Opie, Nicholas; Sabu, Anu; Saunders, Alexia; McPhedran, Michelle; Cardamone, Lisa; McGowan, Ceara; Maxim, Vanessa; Williams, Richard; Fox, Kate; Cicione, Rosemary; Garrett, David; Ahnood, Arman; Ganesan, Kumaravelu; Meffin, Hamish; Burkitt, Anthony; Prawer, Steven; Williams, Chris; Shepherd, RobertPURPOSE: Due to their increased proximity to retinal ganglion cells (RGCs), epiretinal visual prostheses present the opportunity for eliciting phosphenes with low thresholds through direct RGC activation. This study characterised the in vivo performance of a novel prototype monolithic epiretinal prosthesis, containing Nitrogen incorporated ultrananocrystalline (N-UNCD) diamond electrodes. METHODS: A prototype implant containing up to twenty-five 120×120 µm N-UNCD electrodes was implanted into 16 anaesthetised cats and attached to the retina either using a single tack or via magnetic coupling with a suprachoroidally placed magnet. Multiunit responses to retinal stimulation using charge-balanced biphasic current pulses were recorded acutely in the visual cortex using a multichannel planar array. Several stimulus parameters were varied including; the stimulating electrode, stimulus polarity, phase duration, return configuration and the number of electrodes stimulated simultaneously. RESULTS: The rigid nature of the device and its form factor necessitated complex surgical procedures. Surgeries were considered successful in 10/16 animals and cortical responses to single electrode stimulation obtained in 8 animals. Clinical imaging and histological outcomes showed severe retinal trauma caused by the device in-situ in many instances. Cortical measures were found to significantly depend on the surgical outcomes of individual experiments, phase duration, return configuration and the number of electrodes stimulated simultaneously, but not stimulus polarity. Cortical thresholds were also found to increase over time within an experiment. CONCLUSIONS: The study successfully demonstrated that an epiretinal prosthesis containing diamond electrodes could produce cortical activity with high precision, albeit only in a small number of cases. Both surgical approaches were highly challenging in terms of reliable and consistent attachment to and stabilisation against the retina, and often resulted in severe retinal trauma. There are key challenges (device form factor and attachment technique) to be resolved for such a device to progress towards clinical application, as current surgical techniques are unable to address these issues.
- ItemLaminin coated diamond electrodes for neural stimulation(Elsevier B.V., 2020-09) Sikder, Md..Kabir Uddin; Tong, Wei; Pingle, Hitesh; Kingshott, Peter; Needham, Karina; Shivdasani, Mohit; Fallon, James; Seligman, Peter; Ibbotson, Michael; Prawer, Steven; Garrett, DavidThe performance of many implantable neural stimulation devices is degraded due to the loss of neurons around the electrodes by the body's natural biological responses to a foreign material. Coating of electrodes with biomolecules such as extracellular matrix proteins is one potential route to suppress the adverse responses that lead to loss of implant functionality. Concurrently, however, the electrochemical performance of the stimulating electrode must remain optimal to continue to safely provide sufficient charge for neural stimulation. We have previously found that oxygen plasma treated nitrogen included ultrananocrystalline diamond coated platinum electrodes exhibit superior charge injection capacity and electrochemical stability for neural stimulation (Sikder et al., 2019). To fabricate bioactive diamond electrodes, in this work, laminin, an extracellular matrix protein known to be involved in inter-neuron adhesion and recognition, was used as an example biomolecule. Here, laminin was covalently coupled to diamond electrodes. Electrochemical analysis found that the covalently coupled films were robust and resulted in minimal change to the charge injection capacity of diamond electrodes. The successful binding of laminin and its biological activity was further confirmed using primary rat cortical neuron cultures, and the coated electrodes showed enhanced cell attachment densities and neurite outgrowth. The method proposed in this work is versatile and adaptable to many other biomolecules for producing bioactive diamond electrodes, which are expected to show reduced the inflammatory responses in vivo.
- ItemMinimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activity(Nature Publishing Group, 2016-02-08) Oxley, Thomas; Opie, Nicholas; John, Sam; Rindl, Gil; Ronayne, Stephen; Wheeler, Tracey; Judy, Jack; McDonald, Alan; Dornom, Anthony; Lovell, Timothy; Steward, Christopher; Garrett, David; Moffat, Bradford; Lui, Elaine; Yassi, Nawaf; Campbell, Bruce; Wong, Yan; Fox, Kate; Nurse, Ewan; Bennett, Iwan; Bauquier, Sebastien; Lyanage, Kishan; van de Nagel, Nicole; Perucca, Piero; Ahnood, Arman; Gill, Katherine; Yan, Bernard; Churilov, Leonid; French, Christopher; Desmond, Patricia; Horne, Malcolm; Kiers, Lynette; Prawer, Steven; Davis, Stephen; Burkitt, Anthony; Mitchell, Peter; Grayden, David; May, Clive; O'Brien, TerenceHigh-fidelity intracranial electrode arrays for recording and stimulating brain activity have facilitated major advances in the treatment of neurological conditions over the past decade. Traditional arrays require direct implantation into the brain via open craniotomy, which can lead to inflammatory tissue responses, necessitating development of minimally invasive approaches that avoid brain trauma. Here we demonstrate the feasibility of chronically recording brain activity from within a vein using a passive stent-electrode recording array (stentrode). We achieved implantation into a superficial cortical vein overlying the motor cortex via catheter angiography and demonstrate neural recordings in freely moving sheep for up to 190 d. Spectral content and bandwidth of vascular electrocorticography were comparable to those of recordings from epidural surface arrays. Venous internal lumen patency was maintained for the duration of implantation. Stentrodes may have wide ranging applications as a neural interface for treatment of a range of neurological conditions.
- ItemSoft, Flexible Freestanding Neural Stimulation and Recording Electrodes Fabricated from Reduced Graphene Oxide(John Wiley and Sons, 2015-05-04) Apollo, Nicholas; Maturana, Matias; Tong, Wei; Nayagam, David; Shivdasani, Mohit; Foroughi, Javad; Wallace, Gordon; Prawer, Steven; Ibbotson, Michael; Garrett, DavidThere is an urgent need for conductive neural interfacing materials that exhibit mechanically compliant properties, while also retaining high strength and durability under physiological conditions. Currently, implantable electrode systems designed to stimulate and record neural activity are composed of rigid materials such as crystalline silicon and noble metals. While these materials are strong and chemically stable, their intrinsic stiffness and density induce glial scarring and eventual loss of electrode function in vivo. Conductive composites, such as polymers and hydrogels, have excellent electrochemical and mechanical properties, but are electrodeposited onto rigid and dense metallic substrates. In the work described here, strong and conductive microfibers (40–50 μm diameter) wet-spun from liquid crystalline dispersions of graphene oxide are fabricated into freestanding neural stimulation electrodes. The fibers are insulated with parylene-C and laser-treated, forming “brush” electrodes with diameters over 3.5 times that of the fiber shank. The fabrication method is fast, repeatable, and scalable for high-density 3D array structures and does not require additional welding or attachment of larger electrodes to wires. The electrodes are characterized electrochemically and used to stimulate live retina in vitro. Additionally, the electrodes are coated in a water-soluble sugar microneedle for implantation into, and subsequent recording from, visual cortex.