Browsing by Author "Lichter, Samantha"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- ItemDevelopment of a Magnetic Attachment Method for Bionic Eye Applications(Wiley Periodicals, Inc., 2016) Fox, Kate; Meffin, Hamish; Burns, Owen; Abbott, Carla; Allen, Penelope; Opie, Nicholas; McGowan, Ceara; Yeoh, Jonathon; Ahnood, Arman; Luu, Chi; Cicione, Rosemary; Saudners, Alexia; McPhedran, Michelle; Cardamone, Lisa; Villalobos, Joel; Garrett, David; Nayagam, David; Apollo, Nicholas; Ganesan, Kumaravelu; Shivdasani, Mohit; Stacey, Alastair; Escudie, Mathilde; Lichter, Samantha; Shepherd, Robert; Prawer, StephenSuccessful visual prostheses require stable, long-term attachment. Epiretinal prostheses, in particular, require attachment methods to fix the prosthesis onto the retina. The most common method is fixation with a retinal tack; however, tacks cause retinal trauma, and surgical proficiency is important to ensure optimal placement of the prosthesis near the macula. Accordingly, alternate attachment methods are required. In this study, we detail a novel method of magnetic attachment for an epiretinal prosthesis using two prostheses components positioned on opposing sides of the retina. The magnetic attachment technique was piloted in a feline animal model (chronic, nonrecovery implantation). We also detail a new method to reliably control the magnet coupling force using heat. It was found that the force exerted upon the tissue that separates the two components could be minimized as the measured force is proportionately smaller at the working distance. We thus detail, for the first time, a surgical method using customized magnets to position and affix an epiretinal prosthesis on the retina. The position of the epiretinal prosthesis is reliable, and its location on the retina is accurately controlled by the placement of a secondary magnet in the suprachoroidal location. The electrode position above the retina is less than 50 microns at the center of the device, although there were pressure points seen at the two edges due to curvature misalignment. The degree of retinal compression found in this study was unacceptably high; nevertheless, the normal structure of the retina remained intact under the electrodes.
- ItemHermetic diamond capsules for biomedical implants enabled by gold active braze alloys(Elsevier, Ltd., 2015-03) Lichter, Samantha; Escudie, Mathilde; Stacey, Alastair; Ganesan, Kumaravelu; Fox, Kate; Ahnood, Arman; Apollo, Nicholas; Kua, Dunstan; Lee, Aaron; McGowan, Ceara; Saunders, Alexia; Burns, Owen; Nayagam, David; Williams, Richard; Garrett, David; Meffin, Hamish; Prawer, StephenAs the field of biomedical implants matures the functionality of implants is rapidly increasing. In the field of neural prostheses this is particularly apparent as researchers strive to build devices that interact with highly complex neural systems such as vision, hearing, touch and movement. A retinal implant, for example, is a highly complex device and the surgery, training and rehabilitation requirements involved in deploying such devices are extensive. Ideally, such devices will be implanted only once and will continue to function effectively for the lifetime of the patient. The first and most pivotal factor that determines device longevity is the encapsulation that separates the sensitive electronics of the device from the biological environment. This paper describes the realisation of a free standing device encapsulation made from diamond, the most impervious, long lasting and biochemically inert material known. A process of laser micro-machining and brazing is described detailing the fabrication of hermetic electrical feedthroughs and laser weldable seams using a 96.4% gold active braze alloy, another material renowned for biochemical longevity. Accelerated ageing of the braze alloy, feedthroughs and hermetic capsules yielded no evidence of corrosion and no loss of hermeticity. Samples of the gold braze implanted for 15 weeks, in vivo, caused minimal histopathological reaction and results were comparable to those obtained from medical grade silicone controls. The work described represents a first account of a free standing, fully functional hermetic diamond encapsulation for biomedical implants, enabled by gold active alloy brazing and laser micro-machining.