Browsing by Author "Brandli, Alice"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- ItemNeural Responses to Multielectrode Stimulation of Healthy and Degenerate Retina(IOVS, 2017-07) Halupka, Kerry; Abbott, Carla; Wong, Yan; Cloherty, Shaun; Grayden, David; Burkitt, Anthony; Sergeev, Evgeni; Brandli, Alice; Allen, Penelope; Meffin, Hamish; Shivdasani, MohitPurpose: Simultaneous stimulation of multiple retinal electrodes in normally sighted animals shows promise in improving the resolution of retinal prostheses. However, the effects of simultaneous stimulation on degenerate retinae remain unknown. Therefore, we investigated the characteristics of cortical responses to multielectrode stimulation of the degenerate retina. Methods: Four adult cats were bilaterally implanted with retinal electrode arrays in the suprachoroidal space after unilateral adenosine triphosphate (ATP)-induced retinal photoreceptor degeneration. Functional and structural changes were characterized by using electroretinogram a-wave amplitude and optical coherence tomography. Multiunit activity was recorded from both hemispheres of the visual cortex. Responses to single- and multielectrode stimulation of the ATP-injected and fellow control eyes were characterized and compared. Results: The retinae of ATP-injected eyes displayed structural and functional changes consistent with mid- to late-stage photoreceptor degeneration and remodeling. Responses to multielectrode stimulation of the ATP-injected eyes exhibited shortened latencies, lower saturated spike counts, and higher thresholds, compared to stimulation of the fellow control eyes. Electrical receptive field sizes were significantly larger in the ATP-injected eye than in the control eye, and positively correlated with the extent of degeneration. Conclusions: Significant differences exist between cortical responses to stimulation of healthy and degenerate retinae. Our results highlight the importance of using a retinal degeneration model when evaluating the efficacy of novel stimulation paradigms.
- ItemSafety Studies for a 44-Channel Suprachoroidal Retinal Prosthesis: A Chronic Passive Study(IOVS, 2018-03) Abbott, Carla; Nayagam, David; Luu, Chi; Epp, Stephanie; Williams, Richard; Salinas-LaRosa, Cesar; Villalobos, Joel; McGowan, Ceara; Shivdasani, Mohit; Burns, Owen; Leavens, Jason; Yeoh, Jonathon; Brandli, Alice; Thien, Patrick; Zhou, Jenny; Feng, Helen; Williams, Chris; Shepherd, Robert; Allen, PenelopeAbstract Purpose: Following successful clinical outcomes of the prototype suprachoroidal retinal prosthesis, Bionic Vision Australia has developed an upgraded 44-channel suprachoroidal retinal prosthesis to provide a wider field of view and more phosphenes. The aim was to evaluate the preclinical passive safety characteristics of the upgraded electrode array. Methods: Ten normal-sighted felines were unilaterally implanted with an array containing platinum electrodes (44 stimulating and 2 returns) on a silicone carrier near the area centralis. Clinical assessments (color fundus photos, optical coherence tomography, full-field electroretinography, intraocular pressure) were performed under anesthesia prior to surgery, and longitudinally for up to 20 weeks. Histopathology grading of fibrosis and inflammation was performed in two animals at 13 to 15 weeks. Results: Eight animals showed safe electrode array insertion (good retinal health) and good conformability of the array to the retinal curvature. Eight animals demonstrated good mechanical stability of the array with only minor (<2 disc diameters) lateral movement. Four cases of surgical or stability complications occurred due to (1) bulged choroid during surgery, (2) hemorrhage from a systemic bleeding disorder, (3) infection, and (4) partial erosion of thin posterior sclera. There was no change in retinal structure or function (other than that seen at surgery) at endpoint. Histopathology showed a mild foreign body response. Electrodes were intact on electrode array removal. Conclusions: The 44-channel suprachoroidal electrode array has an acceptable passive safety profile to proceed to clinical trial. The safety profile is expected to improve in human studies, as the complications seen are specific to imitations (anatomic differences) with the feline model.