Browsing by Author "Ahnood, Arman"
Now showing 1 - 5 of 5
Results Per Page
Sort Options
- ItemAn all-diamond, hermetic electrical feedthrough array for a retinal prosthesis(Elsevier, 2014-01) Ganesan, Kumaravelu; Garrett, David; Ahnood, Arman; Shivdasani, Mohit; Tong, Wei; Turnley, Ann; Fox, Kate; Meffin, Hamish; Prawer, StevenThe interface between medical implants and the human nervous system is rapidly becoming more and more complex. This rise in complexity is driving the need for increasing numbers of densely packed electrical feedthroughs to carry signals to and from implanted devices. This is particularly crucial in the field of neural prosthesis where high resolution stimulating or recording arrays near peripheral nerves or in the brain could dramatically improve the performance of these devices. Here we describe a flexible strategy for implementing high density, high count arrays of hermetic electrical feedthroughs by forming conducting nitrogen doped nanocrystalline diamond channels within an insulating polycrystalline diamond substrate. A unique feature of these arrays is that the feedthroughs can themselves be used as stimulating electrodes for neural tissue. Our particular application is such a feedthrough, designed as a component of a retinal implant to restore vision to the blind. The hermeticity of the feedthroughs means that the array can also form part of an implantable capsule which can interface directly with internal electronic chips. The hermeticity of the array is demonstrated by helium leak tests and electrical and electrochemical characterisation of the feedthroughs is described. The nitrogen doped nanocrystalline diamond forming the electrical feedthroughs is shown to be non cyctotoxic. New fabrication strategies, such as the one described here, combined with the exceptional biostability of diamond can be exploited to generate a range of biomedical implants that last for the lifetime of the user without fear of degradation.
- ItemDevelopment of a Magnetic Attachment Method for Bionic Eye Applications(Wiley Periodicals, Inc., 2016) Fox, Kate; Meffin, Hamish; Burns, Owen; Abbott, Carla; Allen, Penelope; Opie, Nicholas; McGowan, Ceara; Yeoh, Jonathon; Ahnood, Arman; Luu, Chi; Cicione, Rosemary; Saudners, Alexia; McPhedran, Michelle; Cardamone, Lisa; Villalobos, Joel; Garrett, David; Nayagam, David; Apollo, Nicholas; Ganesan, Kumaravelu; Shivdasani, Mohit; Stacey, Alastair; Escudie, Mathilde; Lichter, Samantha; Shepherd, Robert; Prawer, StephenSuccessful visual prostheses require stable, long-term attachment. Epiretinal prostheses, in particular, require attachment methods to fix the prosthesis onto the retina. The most common method is fixation with a retinal tack; however, tacks cause retinal trauma, and surgical proficiency is important to ensure optimal placement of the prosthesis near the macula. Accordingly, alternate attachment methods are required. In this study, we detail a novel method of magnetic attachment for an epiretinal prosthesis using two prostheses components positioned on opposing sides of the retina. The magnetic attachment technique was piloted in a feline animal model (chronic, nonrecovery implantation). We also detail a new method to reliably control the magnet coupling force using heat. It was found that the force exerted upon the tissue that separates the two components could be minimized as the measured force is proportionately smaller at the working distance. We thus detail, for the first time, a surgical method using customized magnets to position and affix an epiretinal prosthesis on the retina. The position of the epiretinal prosthesis is reliable, and its location on the retina is accurately controlled by the placement of a secondary magnet in the suprachoroidal location. The electrode position above the retina is less than 50 microns at the center of the device, although there were pressure points seen at the two edges due to curvature misalignment. The degree of retinal compression found in this study was unacceptably high; nevertheless, the normal structure of the retina remained intact under the electrodes.
- ItemHermetic diamond capsules for biomedical implants enabled by gold active braze alloys(Elsevier, Ltd., 2015-03) Lichter, Samantha; Escudie, Mathilde; Stacey, Alastair; Ganesan, Kumaravelu; Fox, Kate; Ahnood, Arman; Apollo, Nicholas; Kua, Dunstan; Lee, Aaron; McGowan, Ceara; Saunders, Alexia; Burns, Owen; Nayagam, David; Williams, Richard; Garrett, David; Meffin, Hamish; Prawer, StephenAs the field of biomedical implants matures the functionality of implants is rapidly increasing. In the field of neural prostheses this is particularly apparent as researchers strive to build devices that interact with highly complex neural systems such as vision, hearing, touch and movement. A retinal implant, for example, is a highly complex device and the surgery, training and rehabilitation requirements involved in deploying such devices are extensive. Ideally, such devices will be implanted only once and will continue to function effectively for the lifetime of the patient. The first and most pivotal factor that determines device longevity is the encapsulation that separates the sensitive electronics of the device from the biological environment. This paper describes the realisation of a free standing device encapsulation made from diamond, the most impervious, long lasting and biochemically inert material known. A process of laser micro-machining and brazing is described detailing the fabrication of hermetic electrical feedthroughs and laser weldable seams using a 96.4% gold active braze alloy, another material renowned for biochemical longevity. Accelerated ageing of the braze alloy, feedthroughs and hermetic capsules yielded no evidence of corrosion and no loss of hermeticity. Samples of the gold braze implanted for 15 weeks, in vivo, caused minimal histopathological reaction and results were comparable to those obtained from medical grade silicone controls. The work described represents a first account of a free standing, fully functional hermetic diamond encapsulation for biomedical implants, enabled by gold active alloy brazing and laser micro-machining.
- ItemIn Vivo Feasibility of Epiretinal Stimulation Using Ultrananocrystalline Diamond 1 Electrodes(IOP Publishing, 2020-07) Shivdasani, Mohit; Evans, Mihailo; Burns, Owen; Yeoh, Jonathon; Allen, Penelope; Nayagam, David; Villalobos, Joel; Abbott, Carla; Luu, Chi; Opie, Nicholas; Sabu, Anu; Saunders, Alexia; McPhedran, Michelle; Cardamone, Lisa; McGowan, Ceara; Maxim, Vanessa; Williams, Richard; Fox, Kate; Cicione, Rosemary; Garrett, David; Ahnood, Arman; Ganesan, Kumaravelu; Meffin, Hamish; Burkitt, Anthony; Prawer, Steven; Williams, Chris; Shepherd, RobertPURPOSE: Due to their increased proximity to retinal ganglion cells (RGCs), epiretinal visual prostheses present the opportunity for eliciting phosphenes with low thresholds through direct RGC activation. This study characterised the in vivo performance of a novel prototype monolithic epiretinal prosthesis, containing Nitrogen incorporated ultrananocrystalline (N-UNCD) diamond electrodes. METHODS: A prototype implant containing up to twenty-five 120×120 µm N-UNCD electrodes was implanted into 16 anaesthetised cats and attached to the retina either using a single tack or via magnetic coupling with a suprachoroidally placed magnet. Multiunit responses to retinal stimulation using charge-balanced biphasic current pulses were recorded acutely in the visual cortex using a multichannel planar array. Several stimulus parameters were varied including; the stimulating electrode, stimulus polarity, phase duration, return configuration and the number of electrodes stimulated simultaneously. RESULTS: The rigid nature of the device and its form factor necessitated complex surgical procedures. Surgeries were considered successful in 10/16 animals and cortical responses to single electrode stimulation obtained in 8 animals. Clinical imaging and histological outcomes showed severe retinal trauma caused by the device in-situ in many instances. Cortical measures were found to significantly depend on the surgical outcomes of individual experiments, phase duration, return configuration and the number of electrodes stimulated simultaneously, but not stimulus polarity. Cortical thresholds were also found to increase over time within an experiment. CONCLUSIONS: The study successfully demonstrated that an epiretinal prosthesis containing diamond electrodes could produce cortical activity with high precision, albeit only in a small number of cases. Both surgical approaches were highly challenging in terms of reliable and consistent attachment to and stabilisation against the retina, and often resulted in severe retinal trauma. There are key challenges (device form factor and attachment technique) to be resolved for such a device to progress towards clinical application, as current surgical techniques are unable to address these issues.
- ItemMinimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activity(Nature Publishing Group, 2016-02-08) Oxley, Thomas; Opie, Nicholas; John, Sam; Rindl, Gil; Ronayne, Stephen; Wheeler, Tracey; Judy, Jack; McDonald, Alan; Dornom, Anthony; Lovell, Timothy; Steward, Christopher; Garrett, David; Moffat, Bradford; Lui, Elaine; Yassi, Nawaf; Campbell, Bruce; Wong, Yan; Fox, Kate; Nurse, Ewan; Bennett, Iwan; Bauquier, Sebastien; Lyanage, Kishan; van de Nagel, Nicole; Perucca, Piero; Ahnood, Arman; Gill, Katherine; Yan, Bernard; Churilov, Leonid; French, Christopher; Desmond, Patricia; Horne, Malcolm; Kiers, Lynette; Prawer, Steven; Davis, Stephen; Burkitt, Anthony; Mitchell, Peter; Grayden, David; May, Clive; O'Brien, TerenceHigh-fidelity intracranial electrode arrays for recording and stimulating brain activity have facilitated major advances in the treatment of neurological conditions over the past decade. Traditional arrays require direct implantation into the brain via open craniotomy, which can lead to inflammatory tissue responses, necessitating development of minimally invasive approaches that avoid brain trauma. Here we demonstrate the feasibility of chronically recording brain activity from within a vein using a passive stent-electrode recording array (stentrode). We achieved implantation into a superficial cortical vein overlying the motor cortex via catheter angiography and demonstrate neural recordings in freely moving sheep for up to 190 d. Spectral content and bandwidth of vascular electrocorticography were comparable to those of recordings from epidural surface arrays. Venous internal lumen patency was maintained for the duration of implantation. Stentrodes may have wide ranging applications as a neural interface for treatment of a range of neurological conditions.