DSpace

About the Bionics Institute

 

Bionics Institute Research Online >
Bionic Vision >
Bionic Vision Research Publications >


Title: Determining the Contribution of Retinotopic Discrimination to Localization Performance With a Suprachoroidal Retinal Prosthesis
Authors: Petoe, Matthew
McCarthy, Chris
Shivdasani, Mohit
Sinclair, Nicholas
Scott, Adele
Ayton, Lauren
Barnes, Nick
Bionic Vision Australia Consortium
Keywords: Retinal prosthesis
Suprachoroidal
Localization
Discrimination
Retinitis pigmentosa
Issue Date: Jun-2017
Publisher: IOVS
Citation: Petoe, M. A., C. D. McCarthy, M. N. Shivdasani, N. C. Sinclair, A. F. Scott, L. N. Ayton, N. M. Barnes, R. H. Guymer, P. J. Allen, P. J. Blamey, and Consortium Bionic Vision Australia. 2017. Determining the Contribution of Retinotopic Discrimination to Localization Performance With a Suprachoroidal Retinal Prosthesis. Investigative Ophthalmology & Visual Science. 58(7): 3231-39.
Abstract: Purpose: With a retinal prosthesis connected to a head-mounted camera, subjects can perform low vision tasks using a combination of electrode discrimination and head-directed localization. The objective of the present study was to investigate the contribution of retinotopic electrode discrimination (perception corresponding to the arrangement of the implanted electrodes with respect to their position beneath the retina) to visual performance for three recipients of a 24-channel suprachoroidal retinal implant. Proficiency in retinotopic discrimination may allow good performance with smaller head movements, and identification of this ability would be useful for targeted rehabilitation. Methods: Three participants with retinitis pigmentosa performed localization and grating acuity assessments using a suprachoroidal retinal prosthesis. We compared retinotopic and nonretinotopic electrode mapping and hypothesized that participants with measurable acuity in a normal retinotopic condition would be negatively impacted by the nonretinotopic condition. We also expected that participants without measurable acuity would preferentially use head movement over retinotopic information. Results: Only one participant was able to complete the grating acuity task. In the localization task, this participant exhibited significantly greater head movements and significantly lower localization scores when using the nonretinotopic electrode mapping. There was no significant difference in localization performance or head movement for the remaining two subjects when comparing retinotopic to nonretinotopic electrode mapping. Conclusions: Successful discrimination of retinotopic information is possible with a suprachoroidal retinal prosthesis. Head movement behavior during a localization task can be modified using a nonretinotopic mapping. Behavioral comparisons using retinotopic and nonretinotopic electrode mapping may be able to highlight deficiencies in retinotopic discrimination, with a view to address these deficiencies in a rehabilitation environment. (ClinicalTrials.gov number, NCT01603576).
URI: http://repository.bionicsinstitute.org:8080/handle/123456789/248
ISSN: 1552-5783 (Electronic) 0146-0404 (Linking)
Appears in Collections:Bionic Vision Research Publications

Files in This Item:

File Description SizeFormat
2017_Petoe DeterminingTheContribution.pdf779.28 kBAdobe PDFView/Open
View Statistics

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

DSpace Software Copyright © 2002-2010  Duraspace -