DSpace

About the Bionics Institute

 

Bionics Institute Research Online >
Bionic Hearing >
Bionic Hearing Research Publications >


Title: Effect of current focusing on the sensitivity of inferior colliculus neurons to amplitude-modulated stimulation
Authors: George, Shefin
Shivdasani, Mohit
Fallon, James
Keywords: Cochlear implant
Multipolar stimulation
Current focusing
Modulation detection
Inferior colliculus
Issue Date: Jun-2016
Publisher: American Physiological Society
Citation: George, S. S., M. N. Shivdasani, and J. B. Fallon. 2016. Effect of current focusing on the sensitivity of inferior colliculus neurons to amplitude-modulated stimulation. Journal of Neurophysiology. 116: 1104-16.
Abstract: In multichannel cochlear implants (CIs), current is delivered to specific electrodes along the cochlea in the form of amplitude-modulated pulse trains, to convey temporal and spectral cues. Our previous studies have shown that focused multipolar (FMP) and tripolar (TP) stimulation produce more restricted neural activation and reduced channel interactions in the inferior colliculus (IC) compared with traditional monopolar (MP) stimulation, suggesting that focusing of stimulation could produce better transmission of spectral information. The present study explored the capability of IC neurons to detect modulated CI stimulation with FMP and TP stimulation compared with MP stimulation. The study examined multiunit responses of IC neurons in acutely deafened guinea pigs by systematically varying the stimulation configuration, modulation depth, and stimulation level. Stimuli were sinusoidal amplitude-modulated pulse trains (carrier rate of 120 pulses/s). Modulation sensitivity was quantified by measuring modulation detection thresholds (MDTs), defined as the lowest modulation depth required to differentiate the response of a modulated stimulus from an unmodulated one. Whereas MP stimulation showed significantly lower MDTs than FMP and TP stimulation (P values <0.05) at stimulation </=2 dB above threshold, all stimulation configurations were found to have similar modulation sensitivities at 4 dB above threshold. There was no difference found in modulation sensitivity between FMP and TP stimulation. The present study demonstrates that current focusing techniques such as FMP and TP can adequately convey amplitude modulation and are comparable to MP stimulation, especially at higher stimulation levels, although there may be some trade-off between spectral and temporal fidelity with current focusing stimulation.
URI: http://repository.bionicsinstitute.org:8080/handle/123456789/239
ISSN: 1522-1598 (Electronic) 0022-3077 (Linking)
Appears in Collections:Bionic Hearing Research Publications

Files in This Item:

File Description SizeFormat
2016 George et al Effect of Current Focusing.pdf1.49 MBAdobe PDFView/Open
View Statistics

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

DSpace Software Copyright © 2002-2010  Duraspace -